SAQA All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source.
SOUTH AFRICAN QUALIFICATIONS AUTHORITY 
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: 

Maintain the hearth and sidewall of a converter 
SAQA US ID UNIT STANDARD TITLE
259690  Maintain the hearth and sidewall of a converter 
ORIGINATOR
SGB Manufacturing and Assembly Processes 
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY
-  
FIELD SUBFIELD
Field 06 - Manufacturing, Engineering and Technology Fabrication and Extraction 
ABET BAND UNIT STANDARD TYPE PRE-2009 NQF LEVEL NQF LEVEL CREDITS
Undefined  Regular  Level 2  NQF Level 02 
REGISTRATION STATUS REGISTRATION START DATE REGISTRATION END DATE SAQA DECISION NUMBER
Passed the End Date -
Status was "Reregistered" 
2018-07-01  2023-06-30  SAQA 06120/18 
LAST DATE FOR ENROLMENT LAST DATE FOR ACHIEVEMENT
2024-06-30   2027-06-30  

In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise.  

This unit standard does not replace any other unit standard and is not replaced by any other unit standard. 

PURPOSE OF THE UNIT STANDARD 
This unit standard will be useful to people who are responsible for maintaining the hearth and sidewall of a converter.

People credited with this unit standard are able to:
  • Demonstrate knowledge relating to maintaining the hearth and sidewall of a converter.
  • Prepare to maintain the hearth and sidewall.
  • Maintain the hearth and sidewall.
  • Complete the duties pertaining to the maintenance of the hearth and sidewall of a converter. 

  • LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING 
    It is assumed that learners are already competent in:
  • Communication and mathematical literacy at NQF Level 1. 

  • UNIT STANDARD RANGE 
    N/A 

    Specific Outcomes and Assessment Criteria: 

    SPECIFIC OUTCOME 1 
    Demonstrate knowledge relating to maintaining the hearth and sidewall of a converter. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    The requirements pertaining to a safe, healthy work environment in maintaining the hearth and sidewall and the consequences of not adhering to the above are explained in terms of specified requirements. 

    ASSESSMENT CRITERION 2 
    The importance of maintaining the hearth and sidewall is explained in terms of achieving specified production requirements and up- and down stream operational requirements. 

    ASSESSMENT CRITERION 3 
    Hazards and associated risks pertaining to maintaining the hearth and sidewall are identified through specified risk assessment procedures. 

    ASSESSMENT CRITERION 4 
    The actions to be taken should hazards and risks be encountered are explained in terms of specified requirements. 

    ASSESSMENT CRITERION 5 
    The principal components of the hearth and sidewall are identified and their functions explained in terms of operational requirements. 
    ASSESSMENT CRITERION RANGE 
    Principal components must include:
  • Hearth & sidewall components.
  • Safety devices.
     

  • ASSESSMENT CRITERION 6 
    Lock-out procedures pertaining to the hearth and sidewall maintenance and the consequences of non-compliance are explained in terms of specified requirements. 

    ASSESSMENT CRITERION 7 
    The actions to be taken, should sub-standard conditions and problems be encountered, are explained. In terms of legal and operational requirements. 

    ASSESSMENT CRITERION 8 
    The communication requirements pertaining to the hearth and sidewall maintenance and the consequences of non-compliance are explained in terms of legal and operational requirements. 

    ASSESSMENT CRITERION 9 
    The maintenance parameters and the consequences of not adhering to these are explained in terms of operational requirements. 

    ASSESSMENT CRITERION 10 
    The factors affecting the optimum performance of the hearth and sidewall are explained in terms of operational requirements. 

    SPECIFIC OUTCOME 2 
    Prepare to maintain the hearth and sidewall. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Personal protective and safety equipment is verified, examined and used in accordance with specified requirements. 

    ASSESSMENT CRITERION 2 
    Tools and equipment are verified and examined in accordance with manufacturers requirements. 

    ASSESSMENT CRITERION 3 
    Workplace hazards and associated risks are dealt with in accordance with specified requirements. 

    ASSESSMENT CRITERION 4 
    The hearth and sidewall is examined and substandard conditions are dealt with in accordance with operational requirements. 

    ASSESSMENT CRITERION 5 
    Security requirements pertaining to the hearth and sidewall maintenance are dealt with in accordance with legal and operational requirements. 

    ASSESSMENT CRITERION 6 
    Occupational safety and health procedures towards self and others are maintained in accordance with specified requirements. 

    SPECIFIC OUTCOME 3 
    Maintain the hearth and sidewall. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Personal protective and safety equipment is used in accordance with specified requirements. 

    ASSESSMENT CRITERION 2 
    The maintenance process of the hearth and sidewall expansion is done in accordance with operational requirements. 

    ASSESSMENT CRITERION 3 
    Safe and optimum maintenance is ensured through effective communication. 

    ASSESSMENT CRITERION 4 
    Tools and equipment are used in accordance with manufacturers requirements. 

    ASSESSMENT CRITERION 5 
    Security requirements pertaining to the hearth and sidewall maintenance are dealt with in accordance with legal and operational requirements. 

    ASSESSMENT CRITERION 6 
    Work related hazards and associated risks are dealt with in accordance with operational requirements. 

    ASSESSMENT CRITERION 7 
    The maintenance of the hearth and sidewall is consistent with environmental policy and other relevant requirements. 

    ASSESSMENT CRITERION 8 
    Problems encountered are dealt with in accordance with operational requirements. 

    ASSESSMENT CRITERION 9 
    Occupational safety and health procedures towards self and others are maintained in accordance with specified requirements. 

    SPECIFIC OUTCOME 4 
    Complete the duties pertaining to the maintenance of the hearth and sidewall of a converter. 

    ASSESSMENT CRITERIA
     

    ASSESSMENT CRITERION 1 
    Personal protective and safety equipment is dealt with in accordance with specified requirements. 

    ASSESSMENT CRITERION 2 
    Tools and equipment are dealt with in accordance with manufacturers requirements. 

    ASSESSMENT CRITERION 3 
    Good housekeeping practices are maintained in accordance with specified requirements. 

    ASSESSMENT CRITERION 4 
    Reports are submitted and data recorded in accordance with legal and operational requirements. 


    UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS 
  • Anyone assessing a learner or moderating the assessment of a learner against this unit standard must be registered as an assessor with the relevant Education, Training, Quality, Assurance (ETQA) Body, or with an ETQA that has a Memorandum of Understanding with the relevant ETQA.
  • Any institution offering learning that will enable the achievement of this unit standard must be accredited as a provider with the relevant Education, Training, Quality, Assurance (ETQA) Body, or with an ETQA that has a Memorandum of Understanding with the relevant ETQA.
  • Assessment and moderation of assessment will be overseen by the relevant Education, Training, Quality, Assurance (ETQA) Body, or with an ETQA that has a Memorandum of Understanding with the relevant ETQA, according to the ETQA's policies and guidelines for assessment and moderation.
  • Moderation must include both internal and external moderation of assessments, unless ETQA policies specify otherwise.
  • Anyone wishing to be assessed against this unit standard may apply to be assessed by any assessment agency, assessor or provider institution that is accredited by the relevant ETQA. 

  • UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE 
    The following embedded knowledge will be assessed in an integrated way in the context of the unit standard.

    1. Knowledge relating to maintaining the hearth and sidewall of a converter:
  • The importance of maintaining the hearth and sidewall.
  • The principal components of the hearth and sidewall.
  • Maintenance parameters and the consequences of not adhering to these.
  • Factors affecting the optimum performance of the hearth and sidewall.
  • The maintenance process.

    2. Critical factors relating to adsorbing a dissolved precious metal onto resin:
  • Legal and specified requirements.
  • Achieving specified production requirements.
  • Risk Assessment procedures and actions.
  • Identify the principal components and explain the specification and their functions.
  • Specified communication requirements.
  • Elementary principles of the process.

    3. Processes and events:
  • Preparation.
  • Examination.
  • Metal recovery.
  • Monitor and control.

    4. Causes and effects (Safety and Health):
  • Use of personal protective equipment.
  • Use of tools and equipment.
  • Workplace hazards and associated risks.
  • Housekeeping.

    5. Procedures and techniques:
  • Methods of collecting, analysing, organising, summarising and presenting data.
  • Fault finding and corrective techniques.
  • Handling procedure and controls.

    6. Regulations, legislation, agreements, policies and standards:
  • Safety, health and environmental legislation and regulations.
  • Quality policies, standards and agreements. 

  • UNIT STANDARD DEVELOPMENTAL OUTCOME 
    N/A 

    UNIT STANDARD LINKAGES 
    N/A 


    Critical Cross-field Outcomes (CCFO): 

    UNIT STANDARD CCFO IDENTIFYING 
    Identify and solve problems and make decisions using critical and creative thinking.
  • Note: The learner is able to monitor plant and process conditions, identify anomalies and non-conformances and take appropriate action to resolve the issue with regards to maintaining the hearth and sidewall of a converter. 

  • UNIT STANDARD CCFO WORKING 
    Work effectively with others as a member of a team, group, organisation or community.
  • Note: The learner contributes effectively to teamwork in the metals production process. 

  • UNIT STANDARD CCFO COLLECTING 
    Collect, analyse, organise and critically evaluate information.
  • Note: The learner demonstrates the ability to constantly monitor plant and process conditions, record information effectively and accurately. 

  • UNIT STANDARD CCFO SCIENCE 
    Use science and technology effectively and critically, thus showing responsibility towards the environment and health of others.
  • Note: The learner interacts confidently with the technology which is used to monitor and control conditions in the metals production plant. 

  • UNIT STANDARD CCFO DEMONSTRATING 
    Demonstrate an understanding of the world as a set of related systems by recognising that problem-solving contexts do not exist in isolation.
  • Note: The learner understands the synergy between upstream, downstream and parallel processes, and his/her own role with regards to maintaining the hearth and sidewall of a converter. 

  • UNIT STANDARD ASSESSOR CRITERIA 
    N/A 

    REREGISTRATION HISTORY 
    As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. 

    UNIT STANDARD NOTES 
    Terminology:

    Specified requirements include legal and site-specific requirements and are contained in one or more of the following documents:

    Legal:
  • Relevant Acts, e.g. Mine Health & Safety Act, 1996 (Act No. 29/1996), and Minerals Act and Regulations, 1991 (Act No. 50/1991).
  • Mandatory Codes of Practice.
  • SANS and other relevant standards.
  • Chief Inspector of Mines' Directives.

    Site-Specific:
  • Hazard Identification and Risk Assessments (HIRA).
  • Occupational Health and Safety Risk Management Programme.
  • Managerial Instructions.
  • Mine Standard Procedures.
  • List of Recorded OH&S Risks.
  • Working Guides.
  • Equipment and Materials Specifications. 

  • QUALIFICATIONS UTILISING THIS UNIT STANDARD: 
      ID QUALIFICATION TITLE PRE-2009 NQF LEVEL NQF LEVEL STATUS END DATE PRIMARY OR DELEGATED QA FUNCTIONARY
    Elective  64189   National Certificate: Metals Production  Level 2  NQF Level 02  Passed the End Date -
    Status was "Reregistered" 
    2023-06-30  As per Learning Programmes recorded against this Qual 


    PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: 
    This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here.
     
    NONE 



    All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source.