All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Diagnose and repair integrated starter and alternator combination systems (ISAD) |
SAQA US ID | UNIT STANDARD TITLE | |||
12237 | Diagnose and repair integrated starter and alternator combination systems (ISAD) | |||
ORIGINATOR | ||||
SGB Manufacturing and Assembly Processes | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 06 - Manufacturing, Engineering and Technology | Manufacturing and Assembly | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 5 | Level TBA: Pre-2009 was L5 | 8 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2005-07-19 | 2008-07-19 | SAQA 0160/05 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2009-07-19 | 2012-07-19 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard is replaced by: |
US ID | Unit Standard Title | Pre-2009 NQF Level | NQF Level | Credits | Replacement Status |
376602 | Diagnose and repair integrated starter and alternator combination systems (ISAD) | Level 5 | Level TBA: Pre-2009 was L5 | 8 |
PURPOSE OF THE UNIT STANDARD |
The skills, values and knowledge reflected in this unit standard are required by people in the field of autotronics.
The learning outcomes in this unit standard also contribute to the exit level outcomes required for the autotronics NQF level 5 qualification. Qualifying learners can diagnose and repair integrated starter and alternator combination systems on an automobile. |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
This unit standard is designed as part of a progression.
The credits allocated to this unit standard assume that the learner is competent on the relevant unit standards at the lower level. |
UNIT STANDARD RANGE |
The scope and level of this unit standard is determined by the ranges as indicated under specific outcomes.
The learner should be able to work autonomously. |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Discuss and explain the operation of an integrated starter and alternator (ISAD) system |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Results achieved
1. ISAD system circuits, diagrams and related components' functions and operation are understood 2. Systems is diagnosed, repaired and working to manufacturer's specifications 3. Serviced components are replace/adjusted and meet specifications 4. All defective components are marked, removed and reported 5. Relevant documentation is completed Indicators 1. Appropriate components are chosen 2. Appropriate voltage source is chosen when servicing 3. Tools are selected and used correctly 4. Test equipment is selected and used correctly 5. Safe working practices are adhered to while carrying out activities 6. Appropriate fault finding and diagnostic procedures are used 7. Manufacturer's specifications are adhered to 8. Problems are located and rectified Understanding confirmed Respond to "what if" and "why" questions covering 1. Integrated starter and alternator combination systems 2. Magneto starter/alternator fly wheel 3. Auxiliary power source 4. 12 versus 42 system 5. Control feed back loop 6. Selection and use of components 7. Diagnosis and testing of ISAD systems 8. Consequences of not apply relevant safety practices and procedures 9. Manufacturer's specification manuals |
SPECIFIC OUTCOME 2 |
Discuss and explain the function of (ISAD) system components |
OUTCOME RANGE |
Components include 42V system, rotor, field coils, battery, electronic control unit, supplementary storage battery, auxiliary power sockets, accessory take off. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Results achieved
1. ISAD system circuits, diagrams and related components' functions and operation are understood 2. Systems is diagnosed, repaired and working to manufacturer's specifications 3. Serviced components are replace/adjusted and meet specifications 4. All defective components are marked, removed and reported 5. Relevant documentation is completed Indicators 1. Appropriate components are chosen 2. Appropriate voltage source is chosen when servicing 3. Tools are selected and used correctly 4. Test equipment is selected and used correctly 5. Safe working practices are adhered to while carrying out activities 6. Appropriate fault finding and diagnostic procedures are used 7. Manufacturer's specifications are adhered to 8. Problems are located and rectified Understanding confirmed Respond to "what if" and "why" questions covering 1. Integrated starter and alternator combination systems 2. Magneto starter/alternator fly wheel 3. Auxiliary power source 4. 12 versus 42 system 5. Control feed back loop 6. Selection and use of components 7. Diagnosis and testing of ISAD systems 8. Consequences of not apply relevant safety practices and procedures 9. Manufacturer's specification manuals |
SPECIFIC OUTCOME 3 |
Identify and select ISAD components |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Results achieved
1. ISAD system circuits, diagrams and related components' functions and operation are understood 2. Systems is diagnosed, repaired and working to manufacturer's specifications 3. Serviced components are replace/adjusted and meet specifications 4. All defective components are marked, removed and reported 5. Relevant documentation is completed Indicators 1. Appropriate components are chosen 2. Appropriate voltage source is chosen when servicing 3. Tools are selected and used correctly 4. Test equipment is selected and used correctly 5. Safe working practices are adhered to while carrying out activities 6. Appropriate fault finding and diagnostic procedures are used 7. Manufacturer's specifications are adhered to 8. Problems are located and rectified Understanding confirmed Respond to "what if" and "why" questions covering 1. Integrated starter and alternator combination systems 2. Magneto starter/alternator fly wheel 3. Auxiliary power source 4. 12 versus 42 system 5. Control feed back loop 6. Selection and use of components 7. Diagnosis and testing of ISAD systems 8. Consequences of not apply relevant safety practices and procedures 9. Manufacturer's specification manuals |
SPECIFIC OUTCOME 4 |
Diagnose and test ISAD and related components |
OUTCOME NOTES |
OUTCOME RANGE |
Test equipment include digital code checker, multi meter, test lamps oscilloscope, specialised diagnostic company specific equipment.
Diagnosing includes analysing/interpretation of diagnosing codes on the ECU. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Results achieved
1. ISAD system circuits, diagrams and related components' functions and operation are understood 2. Systems is diagnosed, repaired and working to manufacturer's specifications 3. Serviced components are replace/adjusted and meet specifications 4. All defective components are marked, removed and reported 5. Relevant documentation is completed Indicators 1. Appropriate components are chosen 2. Appropriate voltage source is chosen when servicing 3. Tools are selected and used correctly 4. Test equipment is selected and used correctly 5. Safe working practices are adhered to while carrying out activities 6. Appropriate fault finding and diagnostic procedures are used 7. Manufacturer's specifications are adhered to 8. Problems are located and rectified Understanding confirmed Respond to "what if" and "why" questions covering 1. Integrated starter and alternator combination systems 2. Magneto starter/alternator fly wheel 3. Auxiliary power source 4. 12 versus 42 system 5. Control feed back loop 6. Selection and use of components 7. Diagnosis and testing of ISAD systems 8. Consequences of not apply relevant safety practices and procedures 9. Manufacturer's specification manuals |
SPECIFIC OUTCOME 5 |
Apply the relevant system safety and servicing precautions when working with ISAD |
OUTCOME RANGE |
Servicing precautions as specified in the manufacturer's servicing manual, carry out relevant checks before commissioning. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Results achieved
1. ISAD system circuits, diagrams and related components' functions and operation are understood 2. Systems is diagnosed, repaired and working to manufacturer's specifications 3. Serviced components are replace/adjusted and meet specifications 4. All defective components are marked, removed and reported 5. Relevant documentation is completed Indicators 1. Appropriate components are chosen 2. Appropriate voltage source is chosen when servicing 3. Tools are selected and used correctly 4. Test equipment is selected and used correctly 5. Safe working practices are adhered to while carrying out activities 6. Appropriate fault finding and diagnostic procedures are used 7. Manufacturer's specifications are adhered to 8. Problems are located and rectified Understanding confirmed Respond to "what if" and "why" questions covering 1. Integrated starter and alternator combination systems 2. Magneto starter/alternator fly wheel 3. Auxiliary power source 4. 12 versus 42 system 5. Control feed back loop 6. Selection and use of components 7. Diagnosis and testing of ISAD systems 8. Consequences of not apply relevant safety practices and procedures 9. Manufacturer's specification manuals |
SPECIFIC OUTCOME 6 |
Discuss and report incidents and problems related to ISAD systems and complete fault finding reports |
OUTCOME NOTES |
Discuss and report incidents and problems related to ISAD systems and complete fault finding reports and requisitions. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Results achieved
1. ISAD system circuits, diagrams and related components' functions and operation are understood 2. Systems is diagnosed, repaired and working to manufacturer's specifications 3. Serviced components are replace/adjusted and meet specifications 4. All defective components are marked, removed and reported 5. Relevant documentation is completed Indicators 1. Appropriate components are chosen 2. Appropriate voltage source is chosen when servicing 3. Tools are selected and used correctly 4. Test equipment is selected and used correctly 5. Safe working practices are adhered to while carrying out activities 6. Appropriate fault finding and diagnostic procedures are used 7. Manufacturer's specifications are adhered to 8. Problems are located and rectified Understanding confirmed Respond to "what if" and "why" questions covering 1. Integrated starter and alternator combination systems 2. Magneto starter/alternator fly wheel 3. Auxiliary power source 4. 12 versus 42 system 5. Control feed back loop 6. Selection and use of components 7. Diagnosis and testing of ISAD systems 8. Consequences of not apply relevant safety practices and procedures 9. Manufacturer's specification manuals |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
1. Names and functions of:
2. Purpose of: 3. Attributes, descriptions, characteristics and properties: 4. Sensory cues: 5. Causes and effects, implications of: 6. Procedures and techniques: 7. Regulations, legislation, agreements, policies, standards: 8. Theory: rules, principles laws: 9. Relationship systems: |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identify and solve problems:
|
UNIT STANDARD CCFO WORKING |
Work effectively with others:
|
UNIT STANDARD CCFO ORGANISING |
Organise and manage myself and my activities:
|
UNIT STANDARD CCFO COMMUNICATING |
Communicate effectively:
|
UNIT STANDARD CCFO SCIENCE |
Use science and technology:
|
UNIT STANDARD CCFO DEMONSTRATING |
Demonstrate and understand of the world as a set of related systems:
|
UNIT STANDARD NOTES |
This unit standard has been replaced by unit standard 376602 which is "Diagnose and repair integrated starter and alternator combination systems (ISAD)", Level 5, 8 Credits. |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Elective | 22861 | National Certificate: Autotronics | Level 5 | Level TBA: Pre-2009 was L5 | Passed the End Date - Status was "Reregistered" |
2012-06-30 | MERSETA |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |