All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Install eutectic and multi compartment transport refrigeration systems |
SAQA US ID | UNIT STANDARD TITLE | |||
116716 | Install eutectic and multi compartment transport refrigeration systems | |||
ORIGINATOR | ||||
SGB Air-conditioning Refrigeration and Ventilation | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 06 - Manufacturing, Engineering and Technology | Manufacturing and Assembly | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 3 | NQF Level 03 | 6 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard replaces: |
US ID | Unit Standard Title | Pre-2009 NQF Level | NQF Level | Credits | Replacement Status |
13394 | Install eutectic and multi-compartment transport refrigeration systems | Level 3 | NQF Level 03 | 10 |
PURPOSE OF THE UNIT STANDARD |
Install eutectic systems for transport refrigeration. |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
UNIT STANDARD RANGE |
Commonly applied eutectic transport refrigeration systems. |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Explain and discuss the operation of the eutectic refrigeration system as applied to transport refrigeration. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The difference between the standard refrigeration system and the eutectic system is explained and discussed. |
ASSESSMENT CRITERION 2 |
The advantages and disadvantages of the eutectic refrigeration system are listed and discussed. |
ASSESSMENT CRITERION 3 |
The operation of the eutectic refrigeration system is explained. |
SPECIFIC OUTCOME 2 |
Prepare to install the equipment. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The works order is obtained. |
ASSESSMENT CRITERION 2 |
The truck in which the unit is to be installed is identified. |
ASSESSMENT CRITERION 3 |
The equipment to be installed and the accessories required are obtained from the store and are as specified on the work order. |
ASSESSMENT CRITERION 4 |
The equipment is checked for damage. |
ASSESSMENT CRITERION 5 |
Tools required are obtained and checked. |
ASSESSMENT CRITERION 6 |
The correct installation and operating instructions are obtained. |
SPECIFIC OUTCOME 3 |
Install the equipment. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The eutectic tubes and the supply and return manifolds are installed in accordance with the installation instructions. |
ASSESSMENT CRITERION 2 |
The condensing set is installed. |
ASSESSMENT CRITERION 3 |
The interconnecting piping and accessories are installed and secured correctly and ingress of moisture or dirt is prevented. |
ASSESSMENT CRITERION 4 |
The installation is pressure tested and evacuated correctly. |
ASSESSMENT CRITERION 5 |
The correct refrigerant charge is introduced into the system. |
ASSESSMENT CRITERION 6 |
Refrigerant is handled correctly and no excessive waste occurs. |
ASSESSMENT CRITERION 7 |
The equipment is installed without injury to persons and damage to equipment. |
ASSESSMENT CRITERION 8 |
The vapour barrier and thermal structure is restored. |
SPECIFIC OUTCOME 4 |
Test the unit for operation. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The unit is set in operation. |
ASSESSMENT CRITERION 2 |
The unit is checked for operation. |
ASSESSMENT CRITERION 3 |
Safety measures are applied. |
SPECIFIC OUTCOME 5 |
Carry out post-installation work. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The installation is cleaned properly. |
ASSESSMENT CRITERION 2 |
Packing and waste material is disposed of according to company instructions. |
ASSESSMENT CRITERION 3 |
Job card is completed. |
ASSESSMENT CRITERION 4 |
Completion is reported to supervisor. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
Any person wishing to be assessed against this unit standard may apply to an assessment agency, assessor or provider institution accredited by the relevant ETQA, who may appoint a moderator to be present at the assessment.
The assessor must have knowledge and experience of air-conditioning or refrigeration. |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identify and solve problems:
|
UNIT STANDARD CCFO COLLECTING |
Collect, analyse, organise and critically evaluate information:
|
UNIT STANDARD CCFO COMMUNICATING |
Communicate effectively:
|
UNIT STANDARD CCFO SCIENCE |
Use science and technology effectively and critically:
|
UNIT STANDARD CCFO DEMONSTRATING |
Demonstrate an understanding of the world as a set of related systems:
|
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
This unit standard is replacing unit standard 13394 - 'Install eutectic and multi compartment transport refrigeration systems' - Level 3.
Supplementary information: A eutectic transport refrigeration system consists of a condensing set incorporating a (semi) hermetic compressor, condenser coil and fan and all accessories, electrical equipment and safety instrumentation required and a eutectic evaporator complete with all necessary distributors, expansion valves and manifolds. The condensing set is fitted with a length of power cabling to connect the unit to an external 220 or 380 volt power supply. The condensing set can be installed "nose or undermount". The eutectic evaporator is to be installed inside the truck cooled compartments. The components are interconnected by means of copper piping and/or flexible hoses. The trucks are used for transporting goods at low temperature. |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Elective | 48963 | National Certificate: Air-Conditioning, Refrigeration and Ventilation | Level 3 | NQF Level 03 | Passed the End Date - Status was "Reregistered" |
2009-03-12 | Was MERSETA until Last Date for Achievement |
Elective | 65509 | Further Education and Training Certificate: Air-conditioning, Refrigeration and Ventilation | Level 4 | NQF Level 04 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | MERSETA |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |